- Inverters & Converters[6]
- Alternative Energy Generators[4]
- Solar Energy Systems[6]
- Electricity Generation[1]
- Other Solar Energy Related Products[6]
- Testing Equipment[6]
- Other Mobile Phone Accessories[3]
- Other Measuring & Analysing Instruments[1]
- Other Electrical Equipment[1]
- Other Energy Related Products[3]
- Solar Controllers[6]
- Other Power Supplies[3]
- Power Distribution Equipment[3]
- Terminal Blocks[2]
- Switching Power Supply[1]
- Other Electronic Components[1]
- Uninterrupted Power Supply (UPS)[6]
- Solar Chargers[1]
- Power Accessories[4]
- Chargers[4]
- Copper Pipes[1]
- Electrical Plugs & Sockets[1]
- Connectors[6]
- Terminals[6]
- Circuit Breakers[1]
- Other Switches[1]
- Cable Glands[5]
- Electrical Contacts and Contact Materials[1]
- Rechargeable Batteries[1]
- Contact Person : Ms. Yi Katrina
- Company Name : Yueqing Sandi Electric Co., Ltd.
- Tel : 86-0577-62793760
- Fax : 86-0577-61209955
- Address : Zhejiang,Yueqing,Lvao Industry Zone Liushi Town
- Country/Region : China
- Zip : 325604
Related Product Searches:Battery Charger 400VAC to 220VDC 10A/20A/30A/40A,High Quality,battery charger, 220V battery charger,230D40NZ-3
Battery Charger 400VAC to 220VDC 10A/20A/30A/40A
Main characteristic of the module
lModularization design, realize N+1 backup;
lThe friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.
lRS-485 inrerface, realize “4 remote” function with monitor machine.
lHigh efficiency, Nearly 95%-96%;
lLightly, 230V/10A natural cooling module only 9kg;
lLittle volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;
lAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;
lFunction against reverse pour: each module has been added diode against reverse pour at output terminal.
lLED digital screen, digital calibrate, stable current ,fault alarm
lOutput overvoltage protection
To prevent the disastrous accident caused by outputting overvoltage to electric consumers, there is overvoltage protection circuit in the module. After output overvoltage occurs, the module locks up automatically, the relative module fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system. The overvoltage protection point is set when ex-factory, 320V±5% is set for rated output 220V machine type, 160V±5% is set for rated output 110V machine type.
lOutput current limiting protect
The output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.
lOutput short-circuit protection
When output short circuit, the module draws the output voltage to 0 immediately, limit the short circuit current below 15%limit current point to protect the module. The module will not be damaged under short circuit state for a long time, and can go back to work automatically after debugging.
module project | 230D10ZZ-220AC | 230D05ZZ-3 | 230D20ZZ-3 | 230D20NZ-3 | 230D30NZ-3 | 230D40NZ-3 | |||
rated output current(A) | 10 | 5 | 20 | 20 | 30 | 40 | |||
power(KW) | 3 | 1.5 | 6 | 6 | 9 | 12 | |||
weight(kg) | 9 | 5.2 | 16 | 10.5 | 19 | 19 | |||
cooling method | natural cooling | fan cooling | |||||||
heat sink temperature rise | ≤30°C | ≤20°C | |||||||
rang of input AC(VAC) | min | 187 | 304 | ||||||
Typical value | 220 | 380 | |||||||
max | 253 | 456 | |||||||
rang of the output voltage(VDC) | min | 190 | |||||||
Typical value | 220 | ||||||||
max | 300 | ||||||||
stable voltage accuracy: | ±0.5% | ||||||||
stable current accuracy: | ±1% | ||||||||
PFC | ≥0.93 | ||||||||
Efficiency | ≥95% | ||||||||
noise(dB) | 50 | ||||||||
Storage temperature(°C) | min | -40 | |||||||
Typical value | 25 | ||||||||
max | 60 | ||||||||
working temperature(°C) | min | -10 | |||||||
Typical value | 25 | ||||||||
max | 40 | ||||||||
And machine uneven fluidity | ≤±3% | ||||||||
time delay of start-up(s) | 3~8 | ||||||||
Wave factor | ≤0.2% | ||||||||
Load | 100% rated output current |
Battery Charger 400VAC to 220VDC 10A/20A/30A/40A